Prototipo de Equipo para Apoyo a la Evaluación de Triage para la Secretaria de Salud

dc.contributor.advisorMontaña Quintero, Henryspa
dc.contributor.authorOrjuela Florez, Daniel Felipespa
dc.contributor.authorVarón Herrera, María Alejandraspa
dc.date.accessioned2018-08-08T20:55:47Z
dc.date.available2018-08-08T20:55:47Z
dc.date.created2018-05-21spa
dc.descriptionSe crea un sistema para la evaluación de Triage de los usuarios en sala de urgencias, implementado para la Secretaría de Salud, realizado y configurado en la Facultad Tecnológica de la Universidad Distrital Francisco José de Caldas, para el proyecto curricular de Tecnología en Electrónica. Uno de los principales inconvenientes a la hora de realizar las primeras evaluaciones y diagnósticos de los pacientes en la sala de urgencias es el tiempo de espera al cual se deben someter los mismos. Debido a distintos factores, como el gran congestionamiento que ocurre en las salas, espacio inadecuado de atención, personal médico y de enfermería insuficiente, o pacientes con problemas menores que obstaculizan la atención oportuna de pacientes en condiciones graves o de severidad, la labor de la realización del diagnóstico y el triage se puede ver afectada. Además, se deberá tener en cuenta errores humanos cometidos por el personal encargado de determinar el nivel de urgencia del usuario, Para ello se diseña un prototipo de evaluación de las condiciones críticas del paciente tales como peso, temperatura,oximetría, pulso cardiaco así determinando el nivel de triage en el cual se encuentra, este prototipo cuenta con sistemas de medición de oxigenación y ritmo cardiaco, así como también medición de variables como el peso y la temperatura corporal, dictaminando estas condiciones del usuario. Así mismo enviando estas variables que pueden ser consultadas posteriormente, se concluyó que las medidas de pulso y oximetría eran fiables, pero en cuanto al peso la utilización de más galgas mejoraría la precisión de este y en cuanto al sensor de temperatura es importante tener en cuenta la parte del cuerpo en la cual este se ponga para tener así una medida más fiable.spa
dc.description.abstractA system is created for the evaluation of Triage of the users in the emergency room, implemented for the health secretariat, carried out and configured in the Technological Faculty of the Universidad Distrital Francisco José de Caldas, for the electronic technology project. One of the main drawbacks when making the first evaluations and diagnoses of patients in the emergency room is the waiting time to which they must submit. Due to different factors, such as the great congestion that occurs in the halls, inadequate care space, insufficient medical and nursing personnel, or patients with minor problems that hinder the timely care of patients in severe or severe conditions, the work of the diagnosis and triage can be affected. In addition, human errors committed by the personnel in charge of determining the user's level of urgency must be taken into account. For this purpose, a prototype of evaluation of the critical conditions of the patient such as weight, temperature, oximetry, heart rate is designed, thus determining the level of triage in which it is located, this prototype has systems for measurement of oxygenation and heart rate, as well as measurement of variables such as weight and body temperature, ruling these conditions of the user. Likewise sending these variables that can be consulted later, it was concluded that the measurements of pulse and oximetry were reliable, but in terms of weight the use of more gauges would improve the accuracy of this and as for the temperature sensor it is important to take into account the part of the body in which it is placed in order to have a more reliable measurement.spa
dc.format.mimetypepdfspa
dc.identifier.urihttp://hdl.handle.net/11349/13460
dc.language.isospaspa
dc.rightsAtribución-NoComercial-SinDerivadas 4.0 Internacional*
dc.rights.accesoAbierto (Texto Completo)spa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectTriagespa
dc.subjectMonitoreo de signos vitalesspa
dc.subjectAcondicionamiento de señalesspa
dc.subjectOximetríaspa
dc.subjectPulso cardíacospa
dc.subjectTemperaturaspa
dc.subject.keywordTriagespa
dc.subject.keywordMonitoring of vital signsspa
dc.subject.keywordSignal conditioningspa
dc.subject.keywordOximetryspa
dc.subject.keywordHeart ratespa
dc.subject.keywordTemperaturespa
dc.subject.lembTECNOLOGÍA EN ELECTRÓNICA - TESIS Y DISERTACIONES ACADÉMICASspa
dc.subject.lembENFERMERÍA DE URGENCIAS - APARATOS E INSTRUMENTOSspa
dc.subject.lembMONITOREO DE PACIENTES - PROCESAMIENTO DE DATOSspa
dc.subject.lembDESARROLLO DE PROTOTIPOSspa
dc.titlePrototipo de Equipo para Apoyo a la Evaluación de Triage para la Secretaria de Saludspa
dc.title.titleenglishEquipment Prototype to Support the Triage Evaluation for the Health Secretaryspa
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1fspa
dc.type.degreeMonografíaspa
dc.type.driverinfo:eu-repo/semantics/bachelorThesisspa

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
OrjuelaFlorezDanielFelipe2018.pdf
Tamaño:
856.87 KB
Formato:
Adobe Portable Document Format
Descripción:
Trabajo de Grado
Cargando...
Miniatura
Nombre:
LicenciaYAutorizacion2018.pdf
Tamaño:
1.22 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
OrjuelaFlorezDanielFelipe2018Anexo.pdf
Tamaño:
495.19 KB
Formato:
Adobe Portable Document Format
Descripción:
Anexo

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
7 KB
Formato:
Item-specific license agreed upon to submission
Descripción: