Study of the affinity of Rotavirus with probiotic PEGylated proteins: Development of adapters for the characterization of liquid samples in the spectroscopic ellipsometer of the Universidad Distrital

dc.contributor.advisorHerreño Fierro, César Aurelio
dc.contributor.authorFlores Benavides, Katherin Gineth
dc.contributor.orcidHerreño Fierro, César Aurelio [0000-0003-2394-4322]
dc.date.accessioned2023-08-23T17:22:02Z
dc.date.available2023-08-23T17:22:02Z
dc.date.created2022-10-25
dc.descriptionLa caracterización de muestras líquidas mediante la técnica de elipsometría espectroscópica (SE) requiere, para su optimización, el uso de portamuestras que eviten los errores de medida causados por la tensión superficial de los líquidos, la optimización de la relación señal/ruido, así como la falta de control de un espesor fijo, entre otros. Este trabajo forma parte de un proyecto que tiene como objetivo estudiar la afinidad del Rotavirus con las proteínas probióticas PEGiladas a través de diferentes técnicas de caracterización, incluyendo la SE. Dado que las muestras consideradas son líquidas (solución salina (SS) y polietilenglicol (PEG) suspendido en SS), se desarrollaron diferentes portamuestras adaptables al elipsómetro espectroscópico de la Universidad Distrital, para los fines indicados. La calibración de estos adaptadores y de la técnica de medición se logra, en primera instancia, con pruebas de ensayo y error guiadas por criterios de confiabilidad derivados del contraste de nuestros resultados contra los reportados en la literatura para el caso de sustancias conocidas (agua, alcohol y aceite). La calibración se complementa con la medición de las pseudoconstantes ópticas del PEG suspendido en SS a diferentes concentraciones. Para ello, se utilizan modelos de dispersión empíricos (Sellmeier y Cauchy) y físicos (Lorentz), así como teorías de aproximación al medio efectivo. Como resultado, hemos configurado un dispositivo capaz de mantener muestras líquidas en condiciones adecuadas para su caracterización por SE.spa
dc.description.abstractThe characterization of liquid samples by means of the spectroscopic ellipsometry (SE) technique requires, for its optimization, the use of sample holders that prevent measurement errors caused by the surface tension of the liquids, optimization of the signal-to-noise ratio, as well as the lack of control of a fixed thickness, among others. This work is part of a project that aims to study the affinity of Rotavirus with PEGylated probiotic proteins through different characterization techniques, including SE. Since the samples considered are liquids (saline solution (SS) and polyethylene glycol (PEG) suspended in SS), we developed different sample holders adaptable to the spectroscopic ellipsometer of the Universidad Distrital, for the indicated purposes. The calibration of these adapters and the measurement technique is achieved, in the first instance, with trial-and-error tests guided by reliability criteria derived from the contrast of our results against those reported in the literature for the case of well-known substances (water, alcohol and oil). The calibration is complemented with the measurement of the optical pseudo-constants of PEG suspended in SS at different concentrations. For this, use is made of empirical (Sellmeier and Cauchy) and physical (Lorentz) dispersion models as well as effective medium approximation theories. As a result, we have configured a device capable of maintaining liquid samples in conditions suitable for characterization by SE.spa
dc.format.mimetypepdfspa
dc.identifier.urihttp://hdl.handle.net/11349/31960
dc.language.isospaspa
dc.rightsCC0 1.0 Universal*
dc.rights.accesoAbierto (Texto Completo)spa
dc.rights.accessrightsOpenAccessspa
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/*
dc.subjectEspectroscopíaspa
dc.subjectElipsometríaspa
dc.subjectÍndice de refracciónspa
dc.subjectMuestra líquidaspa
dc.subjectPolarizaciónspa
dc.subjectCelda para líquidosspa
dc.subject.keywordRefractive indexspa
dc.subject.keywordSample holderspa
dc.subject.keywordPolarizationspa
dc.subject.keywordLiquid cellspa
dc.subject.keywordEllipsometryspa
dc.subject.keywordSpectroscopyspa
dc.subject.lembLicenciatura en Física -- Tesis y disertaciones académicas
dc.subject.lembEspesor de películas delgadas
dc.subject.lembCalibración de adaptadores
dc.subject.lembModelos de dispersión
dc.subject.lembMedición de concentraciones
dc.titleStudy of the affinity of Rotavirus with probiotic PEGylated proteins: Development of adapters for the characterization of liquid samples in the spectroscopic ellipsometer of the Universidad Distritalspa
dc.title.titleenglishStudy of the affinity of Rotavirus with probiotic PEGylated proteins: Development of adapters for the characterization of liquid samples in the spectroscopic ellipsometer of the Universidad Distritalspa
dc.typebachelorThesisspa
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1fspa
dc.type.degreeInvestigación-Innovaciónspa
dc.type.driverinfo:eu-repo/semantics/bachelorThesisspa

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
TG_Proyecto_de_investigaci_n.pdf
Tamaño:
3.9 MB
Formato:
Adobe Portable Document Format
Descripción:
Trabajo de Grado
No hay miniatura disponible
Nombre:
Licenciadeusoypublicacion.pdf
Tamaño:
213.51 KB
Formato:
Adobe Portable Document Format
Descripción:
Licencia de uso y publicación

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
7 KB
Formato:
Item-specific license agreed upon to submission
Descripción: