| dc.description | In the compression electrocardiographic signal transmission using vectorial quantification (VQ), is important to protect the information due to the influence than occasional mistakes produced for the high compression rates in the transmission; needing here an error analisys during transmission and the error stimation study, all these to obtain an error control machine that solve the cases that can appear in a random way during the reduced data transmission of the signal. | en-US |
| dc.description | En la transmisión de señal electrocardiográfica comprimida empleando cuantificación vectorial (VQ), es importante proteger la información debido a la influencia que pueden tener los errores, ocasionados en la transmisión por las altas tasas de compresión que se tiene en este caso, siendo necesario un análisis de errores en transmisión y el estudio de estimación de errores, con el objeto de poder establecer la máquina de control de error que resuelva los casos que se puedan presentar de manera aleatoria durante la transmisión de los datos comprimidos de la señal. | es-ES |
| dc.format | application/pdf | |
| dc.format | text/html | |
| dc.identifier | https://revistas.udistrital.edu.co/index.php/reving/article/view/2189 | |
| dc.identifier | 10.14483/23448393.2189 | |
| dc.identifier.uri | http://hdl.handle.net/11349/19513 | |
| dc.language | spa | |
| dc.publisher | Universidad Distrital Francisco José de Caldas | en-US |
| dc.relation | https://revistas.udistrital.edu.co/index.php/reving/article/view/2189/2936 | |
| dc.relation | https://revistas.udistrital.edu.co/index.php/reving/article/view/2189/2937 | |
| dc.source | Ingeniería; Vol 5 No 2 (2000): July - December; 17-28 | en-US |
| dc.source | Ingeniería; Vol. 5 Núm. 2 (2000): Julio - Diciembre; 17-28 | es-ES |
| dc.source | 2344-8393 | |
| dc.source | 0121-750X | |
| dc.subject | Electrocardiographic signal (ecg) | en-US |
| dc.subject | vector quantization ( VQ) | en-US |
| dc.subject | mean shape vector quantizer (VQ-VMF) | en-US |
| dc.subject | percent | en-US |
| dc.subject | root-meansquare difference (PRD) | en-US |
| dc.subject | noise white | en-US |
| dc.subject | interliving | en-US |
| dc.subject | concatenates codes. | en-US |
| dc.subject | Señal electrocardiográfica (ecg) | es-ES |
| dc.subject | cuantificación vectorial (VQ) | es-ES |
| dc.subject | cuantificador vectorial valor medio forma de onda (VQ-VMF) | es-ES |
| dc.subject | diferencia en porcentaje de la raíz cuadrática media (PRD) | es-ES |
| dc.subject | ruido blanco | es-ES |
| dc.subject | intercalado | es-ES |
| dc.subject | códigos concatenados | es-ES |
| dc.subject | Señal electrocardiográfica (ecg) | es-ES |
| dc.subject | cuantificación vectorial (VQ) | es-ES |
| dc.subject | cuantificador vectorial valor medio forma de onda (VQ-VMF) | es-ES |
| dc.subject | diferencia en porcentaje de la raíz cuadrática media (PRD) | es-ES |
| dc.subject | ruido blanco | es-ES |
| dc.subject | intercalado | es-ES |
| dc.subject | códigos concatenados. | es-ES |
| dc.title | Error en transmisión de datos de señal electrocardiográfica comprimida empleando cuantificación vectoral | es-ES |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:eu-repo/semantics/publishedVersion | |
| dc.type.coar | http://purl.org/coar/resource_type/c_6501 |