dc.descriptionThis article, describes the search and development of a system developed for the imaging time of flight diffraction, TOFD. The process to generate them is achieved based on signal acquisition-scan, resulting from the scanning of a specimen metal using ultrasound, and the subsequent group of the same type for generating a two dimensional image, called D-Scan. Because the methodology to obtain the signals imply a displacement of the ultrasonic transducers in the direction perpendicular to the cross section of which is desired to obtain the image deformation occurs in this prevents reliable use dictate when an assessment of a trial. To solve the problem developed an algorithm which consists of two parts: the sample filtered and the alignment thereof. The algorithm was implemented in a C++ within experimental system TOFD imaging and displaying the results to explore the welded steel in a test tubeen-US
dc.descriptionEste artículo describe la investigación y el desarrollo de un sistema para la formación de imágenes por difracción de tiempo de vuelo (TOFD). El proceso para generarlas se logra con base en la adquisición de señales A-Scan, producto de la exploración de una probeta metálica utilizando ultrasonido, y la posterior agrupación de estas para generar un tipo de imagen bidimensional, denominada D-Scan. Dado que la metodología para obtener las señales implica un desplazamiento de los transductores de ultrasonido en dirección perpendicular a la sección transversal de la cual se desea obtener la imagen, se produce una deformación en esta que impide su utilización confiable a la hora de dictaminar una evaluación de una inspección. Para solucionar el problema se desarrolló un algoritmo que consta de dos partes: el filtrado de las muestras y su alineamiento. El algoritmo se implementó en una aplicación de C# dentro del sistema experimental de generación de imágenes TOFD. Se presentan los resultados obtenidos al explorar la unión soldada en una probeta de acero.es-ES
dc.formatapplication/pdf
dc.formattext/html
dc.identifierhttps://revistas.udistrital.edu.co/index.php/visele/article/view/5506
dc.identifier10.14483/22484728.5506
dc.identifier.urihttp://hdl.handle.net/11349/21814
dc.languagespa
dc.publisherUniversidad Distrital Francisco José de Caldases-ES
dc.relationhttps://revistas.udistrital.edu.co/index.php/visele/article/view/5506/7036
dc.relationhttps://revistas.udistrital.edu.co/index.php/visele/article/view/5506/7222
dc.rightsDerechos de autor 2013 Visión Electrónica: algo más que un estado sólidoes-ES
dc.sourceVisión electrónica; Vol 7 No 2 (2013); 28-35en-US
dc.sourceVisión electrónica; Vol. 7 Núm. 2 (2013); 28-35es-ES
dc.source2248-4728
dc.source1909-9746
dc.subjectUltrasounden-US
dc.subjectTOFDen-US
dc.subjectA-Scanen-US
dc.subjectD-Scanen-US
dc.subjectUltrasonidoes-ES
dc.subjectTOFDes-ES
dc.subjectA-Scanes-ES
dc.subjectD-Scanes-ES
dc.titleAlgorithm to reduce distortion of images ultrasonic in non destructive testingen-US
dc.titleAlgoritmo que reduce distorsion de imagenes ultrasonicas en ensayos no destructivoses-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.type.coarhttp://purl.org/coar/resource_type/c_6501

Archivos