Climate control units for Data Center
dc.contributor.author | Suarez Cruz, Ivan Leonardo | spa |
dc.contributor.author | Escobar Díaz, Andrés | spa |
dc.contributor.author | Vacca González, Harold | spa |
dc.date | 2019-06-30 | |
dc.date.accessioned | 2019-09-19T21:52:03Z | |
dc.date.available | 2019-09-19T21:52:03Z | |
dc.description | The execution of an Engineering Project - whose requirements and characteristics implies an exhaustive analysis of needs, environments, operational risks, regulations, equipment and instruments, physical spaces, documentation, and budgetary resources - involves the development of three sequential and complementary phases: Conceptual, Basic and Detail; whose results are: a State of the Art of the system-solution feasible to install, the Architecture and characteristics of equipment and elements of the system-solution, and the specifications of Equipment, instruments, materials and resources to implement the system-solution, respectively. This article reviews, taking as a reference a mathematical model of the three components of the Air Conditioning Units: Compressor, Condenser and Evaporator, the corresponding phases to project Air Conditioning Units in Data Center (ACUDC) according to requirements, norms and technical and engineering characteristics of implementation. Finally, success cases of Data Center implemented and its respective air conditioning systems are presented. | en-US |
dc.description | La ejecución de un proyecto de ingeniería -cuyos requerimientos y características supone el análisis exhaustivo de necesidades, entornos, riesgos de operación, normatividad, equipos e instrumentos, espacios físicos, documentación, y recursos presupuestales- involucra el desarrollo de tres fases secuenciales y complementarias: conceptual, básica y de detalle; cuyos resultados son: un Estado del Arte del sistema-solución factible a instalar, la Arquitectura y características de equipos y elementos del sistema-solución, y las especificaciones de Equipos, instrumentos, materiales y recursos para implementar el sistema-solución, respectivamente. En el presente artículo se revisan, tomando como referencia un modelo matemático de los tres componentes de las Unidades de Climatización: compresor, condensador y evaporador, las fases correspondientes para proyectar Unidades de Climatización en Centro de Datos (UCDC, por sus siglas en ingles) de acuerdo con requerimientos, normas, y características técnicas e ingenieriles de implementación. Finalmente se presentan casos de éxito de centro de datos implementados y los sistemas de climatización respectivos. | es-ES |
dc.format | application/pdf | |
dc.identifier | https://revistas.udistrital.edu.co/index.php/vinculos/article/view/15273 | |
dc.identifier | 10.14483/2322939X.15273 | |
dc.identifier.uri | http://hdl.handle.net/11349/21647 | |
dc.language | spa | |
dc.publisher | Universidad Distrital Francisco José de Caldas | es-ES |
dc.relation | https://revistas.udistrital.edu.co/index.php/vinculos/article/view/15273/15130 | |
dc.rights | http://creativecommons.org/licenses/by-nc/4.0 | es-ES |
dc.source | Revista Vínculos; v. 16 n. 1 (2019): Número preliminar | pt-BR |
dc.source | Revista vínculos; Vol. 16 Núm. 1 (2019): Número preliminar | es-ES |
dc.source | Revista Vínculos; Vol 16 No 1 (2019): Número preliminar | en-US |
dc.source | 2322-939X | |
dc.source | 1794-211X | |
dc.subject | air conditioning | en-US |
dc.subject | chiller | en-US |
dc.subject | condenser | en-US |
dc.subject | evaporator | en-US |
dc.subject | humidifier | en-US |
dc.subject | model | en-US |
dc.subject | refrigeration | en-US |
dc.subject | aire acondicionado | es-ES |
dc.subject | chiller | es-ES |
dc.subject | condensador | es-ES |
dc.subject | evaporador | es-ES |
dc.subject | humidificador | es-ES |
dc.subject | modelo | es-ES |
dc.subject | refrigeración | es-ES |
dc.title | Climate control units for Data Center | en-US |
dc.title | Unidades de climatización para centro de datos | es-ES |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion | |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 |