Direct reconstruction of images by means of magnetic resonance of unequal specimens in K space

dc.contributor.authorBonilla Romero, Clara Inésspa
dc.contributor.authorCancino de Greiff, Héctor Fspa
dc.date2007-11-30
dc.date.accessioned2019-09-19T21:08:06Z
dc.date.available2019-09-19T21:08:06Z
dc.descriptionThe suggested investigation was centered in the search of a direct process of reconstruction of MR images of non-uniform samples in the dominion space- frequency in non-Cartesian space k, specifically on trajectories of spiral type.On the method of direct reconstruction it is not required convolution's kernel, but the computational process is very strong, because each pixel is computed as the Fourier summation, which is very strong consumer of time. With the purpose of improving the precision of reconstruction and the computational efficiency the method of Equal Phase Line (EPL) is developed, on which the characterization of the random function of average quadratic error of reconstruction is made, by means of statistical inference of the parameters of the probability function, and the random simulation of the contamination with Gaussian white noise on the no uniform samples, with the application of the simulation method of Montecarlo.en-US
dc.descriptionLa investigación propuesta se centró en la búsqueda de un proceso directo de reconstrucción de imágenes de resonancia magnética por muestras no uniformes en el dominio espacio-frecuencia --espacio k no cartesiano-- específicamente sobre trayectorias de tipo espiral. En el método de reconstrucción directa no se requiere del kernel de convolución, pero debido a que se debe realizar la sumatoria de Fourier para cada pixel, el proceso computacional consume mucho tiempo. Con la finalidadde mejorar la precisión de reconstrucción y la eficiencia computacional, se desarrolla el método de líneas de igual fase EPL (Equal Phase Line), sobre el que se realiza la caracterización de la función aleatoria de error cuadrático medio de reconstrucción, mediante inferencia estadística de los parámetros de la función de probabilidad y la simulación aleatoria sobre las muestras no uniformes con la contaminación con ruido blanco Gaussiano y con la aplicación del método de simulación de Montecarlo.es-ES
dc.formatapplication/pdf
dc.formattext/html
dc.identifierhttps://revistas.udistrital.edu.co/index.php/revcie/article/view/295
dc.identifier10.14483/23448350.295
dc.identifier.urihttp://hdl.handle.net/11349/16437
dc.languagespa
dc.publisherUniversidad Distrital Francisco José de Caldases-ES
dc.relationhttps://revistas.udistrital.edu.co/index.php/revcie/article/view/295/420
dc.relationhttps://revistas.udistrital.edu.co/index.php/revcie/article/view/295/421
dc.sourceRevista Científica; No 10 (2008): REVISTA CIENTÍFICA Enero-diciembre; 56-68en-US
dc.sourceRevista científica; Núm. 10 (2008): REVISTA CIENTÍFICA Enero-diciembre; 56-68es-ES
dc.source2344-8350
dc.source0124-2253
dc.subjectDirect reconstruction EPLen-US
dc.subjectSpectroscopy of Magnetic Resonante.en-US
dc.subjectDirect reconstruction EPLen-US
dc.subjectSpectroscopy of Magnetic Resonante.en-US
dc.subjectReconstrucción directa EPLes-ES
dc.subjectespectroscopia de resonancia magnética.es-ES
dc.subjectReconstrucción directa EPLes-ES
dc.subjectespectroscopia de resonancia magnética.es-ES
dc.titleDirect reconstruction of images by means of magnetic resonance of unequal specimens in K spaceen-US
dc.titleReconstrucción directa de imágenes por resonancia magnética de Muestras no uniformes en el espacio kes-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.type.coarhttp://purl.org/coar/resource_type/c_6501

Archivos