Login
FAQ

Repositorio Institucional

View Item 
  •   DSpace Home
  • Producción Editorial Universidad Distrital Francisco José de Caldas
  • Revistas
  • Tecnura
  • View Item
  •   DSpace Home
  • Producción Editorial Universidad Distrital Francisco José de Caldas
  • Revistas
  • Tecnura
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Estudio experimental de potencias, factor de potencia y energía eléctrica en cargas industriales tomando como referencia la norma IEEE Std 1459-2010

Experimental study of powers, power factor and energy in industrial loads by reference to IEEE STD 1459-2010

Thumbnail
Author
Daza Urrego, Alexander
Buriticá Arboleda, Clara Inés
Garzón Rodríguez, Yaqueline
Metadata
Show full item record

Abstract

Las potencias eléctricas y factor de potencia (FP) son variables eléctricas que inciden a nivel industrial en el cálculo del costo de la energía eléctrica consumida; para su obtención generalmente se utilizan medidores digitales o analizadores de calidad (PQA) que emplean diferentes algoritmos o metodologías para el cálculo de la energía eléctrica, encontrándose diferencias importantes al comparar los registros obtenidos para cada una de las variables medidas. El presente artículo realiza un estudio experimental para obtener las variables eléctricas a partir de lo estipulado en la metodología señalada por norma IEEE Std 1459-2010, que se toma como referente para comparar valores para potencia reactiva que varían hasta un 40% y potencia aparente y factor de potencia hasta un 20%. Error que se atribuye a que algunos equipos de medida digitales no analizan el sistema trifásico como único y real sino como la suma de tres sistemas independientes e ideales.

Abstract

Electric power and power factor (PF) are electric variables affecting industrial level for the calculation of the cost of electricity consumed; generally for its securing digital meters or quality analyzers (PQA) are generally used, applying different algorithms or methodologies for calculating electric power, finding significant differences when comparing the obtained records to each of the measured variables. This article takes an experimental study for electrical variables from the provisions of the methodology outlined by IEEE Std 1459-2010, which is taken as a reference to compare values for reactive power ranging up to 40% and apparent power factor to 20%. Error attributed to the fact that some digital equipment do not analyze the measurement phase as the only and real system, but as the sum of three independent and ideal systems.

Link to resource

https://revistas.udistrital.edu.co/index.php/Tecnura/article/view/10371
https://doi.org/10.14483/22487638.10371
URI
http://hdl.handle.net/11349/20918
Collections
  • Tecnura [797]

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Universidad Distrital Francisco José de Caldas - Biblioteca UDFJC

Institución de Educación Superior sujeta a inspección y vigilancia por el Ministerio de Educación Nacional | Acuerdo de creación N° 10 de 1948 del Concejo de Bogotá  | Acreditación Institucional de Alta Calidad - Resolución N° 23096 del 15 de diciembre del 2016

 Calle 13 No. 31 - 75 Bogotá D.C. - República de Colombia |  (+57 1) 3239300  |  Lunes a viernes de 8 a.m. a 5 p.m.