Jaramillo Matta, Adolfo AndrésRodríguez Perilla, Alex DavidMartínez Fuentes, Fabian Arturo2015-11-252015-11-252015-11-05http://hdl.handle.net/11349/2452Los motores de inducción trifásicos son máquinas electromecánicas altamente confiables y eficientes, pero susceptibles a diferentes perturbaciones eléctricas como los desequilibrios de tensión, los cuales son una perturbación difícil de mitigar, que pueden desencadenar problemas a nivel industrial y a su vez causar pérdidas monetarias. Por lo tanto se requiere analizar el comportamiento y el impacto de los desequilibrios de tension sobre los motores de induccion. Para cuantificar estos desequilibrios en una red eléctrica, existen cuatro métodos de cálculo estandarizados internacionalmente por: NEMA (National Electrical Manufacturers Association), IEEE (The Institute of Electrical and Electronics Engineers) e IEC (International Electrotechnical Commission). Pero cada una de estas calcula de manera diferente los DdT y por ende para una misma condición de desbalance se pueden presentar diferentes porcentajes de DdT en función de la normativa utilizada. Esto puede generar una problemática entre las normativas usadas por cada país y/o fabricante, cuando los dispositivos han sido diseñados para uso internacional. Por este motivo, se determinaron un total de 29977 casos de DdT, para comparar y analizar las posibles diferencias en los efectos causados en el MdI sobre las variables: par mecánico, velocidad del eje, corriente de línea y eficiencia, cuando estos se calculan mediante las metodologías planteadas por las normativas internacionales.Three-phase Induction Motors are electromechanical machines highly reliable and efficient, but susceptible to different electrical disturbances such as voltage unbalances, which are difficult to mitigate disturbance, which can bring problems at industrial level, and in turn cause monetary losses. Therefore it is required to analyze its behavior and the impact of voltage unbalances on the Three-phase Induction Motors. To quantify these unbalances in a power grid, there are four methods for calculating given by: NEMA (National Electrical Manufacturers Association), IEEE (The Institute of Electrical and Electronics Engineers) and IEC (International Electro technical Commission). But each one of these calculates differently the voltage unbalances and for a same condition of unbalance may occur varying percentages of voltage unbalance according with the standard used. This can create a problem when devices have been designed for international use. For this reason, a total of 29977 cases of voltage unbalances, were determined to compare and analyze the possible differences in the effects caused on the Three-phase Induction Motors on the variables: mechanical torque, speed, current and efficiency, when these are calculated by international standards.pdfspaAtribución-NoComercial-SinDerivadas 4.0 Internacionalhttp://creativecommons.org/licenses/by-nc-nd/4.0/DesequilibriosMotoresIEEEIECNEMAComparativa entre los efectos de los desequilibrios de tensión sobre los motores de inducción trifásicos cuando se utilizan las definiciones dadas por la IEEE, IEC y NEMA.Ingeniería eléctrica - Tesis y disertaciones académicasMotores de inducción trifásicosMotores trifásicosInstitute of Electrical and Electronics Engineers. EEENational Electrical Manufacturers Association. NEMAInternational Electrotechnical Commission. IECinfo:eu-repo/semantics/restrictedAccessComparison between the effects of voltage unbalances on the three phase induction motors when the definitions given by the IEEE, IEC and NEMA are used.UnbalanceMotorsIEEEIECNEMARestringido (Solo Referencia)info:eu-repo/semantics/bachelorThesis